Problem 1 - Light Does Not Turn On at Night
Check in order: 1) Battery voltage (measure at controller terminals with multimeter): below 11.5V (12V system) = battery over-discharged, wait 2–3 sunny days. If voltage does not recover, battery is damaged. 2) Photocell/sensor: cover it with cloth - if light turns on, sensor is faulty or shaded. 3) Controller LED status indicators: green flash = normal, red = fault. Consult controller manual for fault codes. 4) LED driver connection: check for loose terminals at LED input. 5) Fuse: some controllers have an inline fuse on the load output - check and replace if blown. 6) Controller settings: verify controller is not in 'manual off' mode (button accidentally pressed).
Problem 2 - Light is Dimmer Than Before
Gradual dimming over months: panel soiling (most likely - clean panel first). Battery aging - capacity has dropped below 70%, battery needs replacement. LED chip degradation - normal after 30,000+ hours (7+ years at 12h/day). Controller set to permanent dim mode - verify dimming schedule settings. Sudden dimming onset: battery partially discharged (recent cloudy period) - wait for sunny weather recharge. Controller protection triggered (low battery dim mode) - battery recovering from over-discharge. Verify by measuring panel output voltage at solar noon and battery charge voltage.
Problem 3 - Battery Not Charging
Panel voltage at solar noon should be 17–21V (for 12V system). If below 15V: panel may be shaded, dirty, or damaged. Check: clean panel, verify no new shade obstruction, measure panel open-circuit voltage with multimeter (should be 21–22V). If panel voltage is OK but battery voltage does not rise during the day: controller may be faulty (replace controller) or battery has internal failure (replace battery). Check controller-to-battery wiring - a corroded positive terminal can prevent charging even with good panel output.
Problem 4 - Light Turns On During the Day
The photocell is seeing 'dark' even in daylight. Causes: photocell sensor window is dirty - clean the small lens on the controller or fixture body. Photocell is shaded by a newly positioned mounting bracket, bird nest, or leaves. Photocell has failed (resistance stuck high) - replace controller or photocell module. Controller in 'always on' test mode - check DIP switches or app settings. Wire to photocell is broken - if photocell is wired as normally-closed, a broken wire simulates darkness.
Problem 5 - Light Works Intermittently
Works some nights, not others: marginal battery - just barely sufficient for full-night operation. Cloudy day = light works half night; sunny day = works full night. Battery replacement imminent. Check battery voltage at dusk (should be 13.0–13.2V for LiFePO4 after a full sunny day charge). Works initially then dims and cuts off: battery depletes mid-night - either battery aging or excessive load. Verify LED current draw matches controller settings. Works in winter, not in monsoon: panel undersized for reduced monsoon irradiance - may need panel upgrade or battery capacity increase.